SonaSpray "fc" Acoustic Finish Specifications
PART 1 – GENERAL
1.01 Section Includes
- Sprayed cellulose finish system.
1.02 Related Items
- Clips, hangers, supports, sleeves and other attachments to spray bases are to be placed by other trades prior to the application of sprayed insulation.
- Ducts, piping, conduit or other suspended equipment shall not be positioned until after the application of sprayed insulation.
1.03 Submittals
- Copy of manufacturer’s ISO 9001:2008 Certification.
- Submit 2 copies of test reports indicating compliance with the following:
- Minimum light reflectivity:
- Arctic White: 81+
- White: 73+
- NRC values per ASTM C-423 conducted by a NVLAP certified testing laboratory:
SonaSpray “fc” on Solid Backing |
Inches |
125 HZ |
250 HZ |
500 HZ |
1000 HZ |
2000 HZ |
4000 HZ |
NRC |
0.50” |
.08 |
.16 |
.46 |
.87 |
1.07 |
1.12 |
.65 |
1.00” |
.12 |
.38 |
.88 |
1.15 |
1.15 |
1.15 |
.90 |
|
SonaSpray “fc” on Ribbed Metal Deck |
Inches |
125 HZ |
250 HZ |
500 HZ |
1000 HZ |
2000 HZ |
4000 HZ |
NRC |
0.75” |
.17 |
.58 |
.91 |
.89 |
.87 |
.84 |
.80 |
- Flame Spread Index: 5 ASTM E-84/UL 723
- Smoke Developed: 5 ASTM E-84/UL 723
- Bond Strength
SonaSpray “fc” >600 psf ASTM E-736
SonaSpray “fc” Dura-K >900 psf ASTM E-736
- Compression Strength
SonaSpray “fc” >400 psf ASTM E-761
SonaSpray “fc” Dura-K >600 psf ASTM E-761
- Comply with IBC 803.3/2009 IBC 803.10 stability requirements for interior finishes.
- Manufacturer’s written certification that product contains no asbestos, fiberglass or other man-made mineral fibers.
Quality Assurance
- Manufacturer must have a current listing with ICC.
- Manufacturer must be in compliance with the 2006 IBC.
- Manufacturer must be ISO 9001:2008 Certified.
- Applicator: Licensed by manufacturer.
- Manufacturer must subscribe to independent laboratory follow-up inspection services of Underwriters Laboratories. Each bag shall be labeled accordingly.
- Mock-up: Apply a 100 square foot representative sample to be reviewed by the Architects and/or Owner prior to proceeding.
1.05 Delivery, Storage and Handling
- Deliver in original, unopened containers bearing name of manufacturer, product identification and reference to U.L. testing.
- Store materials dry, off ground and under cover.
- Protect liquid adhesive from freezing.
PART 2 – PRODUCTS
2.01 Acceptable Manufacturers
- International Cellulose Corporation
12315 Robin Boulevard
Houston, Texas 77045
(713) 433-6701 or (800) 444-1252
FAX: (713) 433-2029
- For approved applicators contact ICC at (800) 444-1252
2.02 Materials (Specify desired product)
- SonaSpray “fc” Acoustical Finish (4:1 Adhesive Ratio)
- SonaSpray “fc” Dura-K (3:1 Adhesive Ratio)
- Color shall be _________________________.
PART 3 – EXECUTION
3.01 Examination
- Examine surfaces and report unsatisfactory conditions in writing. Do not proceed until unsatisfactory conditions are corrected.
- Verify surfaces to receive spray insulation to determine if priming/sealing is required to ensure bonding and/or to prevent discoloration caused by migratory stains.
3.02 Preparation
- Provide masking, drop cloths or other satisfactory coverings for materials/surfaces that are not to receive insulation to protect from over-spray.
- Coordinate installation of the sprayed cellulose fiber with work of other trades.
- Prime surfaces as required by manufacturer’s instructions or as determined by examination.
3.03 Installation
- Average thickness to achieve NRC of 0.65 or greater.
- Install spray applied acoustical finish according to manufacturer’s recommendations.
- Cure material with continuous natural or mechanical ventilation.
- Remove and dispose of over spray.
3.04 Protection
- Protect finished installation under provisions of Division 1.
|